Availability | on demand | |
Application | Work area, patch cord cable | |
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T | ||
IEEE 802.5 16 MB: ISDN; TPDDI; ATM; PoE | ||
acc. to Standard | EN50288-3-2 | |
EN50173 | ||
EIA-TIA 568 | ||
CEI-UNEL 36762 | ||
Reaction to Fire | EN50575 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 0,48 7x0,16 |
material | Cu | |
Dielectric | Ø mm | 0,80 |
material | PE | |
Outer Sheath | Ø mm | 5,1 |
material | LSZH | |
PHYSICAL DATA | ||
Copper Content | kg/km | 10,8 |
Cable Weight | kg/km | 31,5 |
Min bending radius x 1/n | mm | 20/40 |
Max.Tensile Strength | N | 100 |
ELECTRICAL DATA | ||
Impedance | Ohm | 100±5@100 MHz |
Capacitance of Twisted Pair (@800Hz) | pF/m | 48 |
Velocity Ratio | % | 67 |
Attenuation (at 20°C ) | ||
at 1 MHz | dB/10m | 0,3 |
at 10 MHz | dB/10m | 0,9 |
at 20 MHz | dB/10m | 1,3 |
at 31,2 MHz | dB/10m | 1,6 |
at 62,5 MHz | dB/10m | 2,4 |
at 100 MHz | dB/10m | 3,0 |
NEXT | ||
at 1 MHz | dB | 71,0 |
at 10 MHz | dB | 56,0 |
at 20 MHz | dB | 51,0 |
at 31,2 MHz | dB | 49,0 |
at 62,5 MHz | dB | 44,0 |
at 100 MHz | dB | 41,0 |
Coupling Attenuation | dB | > 45 |
DC Conductor Resistance | Ohm/km | 130,0 |
Loop resistance | Ohm/km | 260,0 |
Sheath Insulation Voltage (DC, 1 min) | kV | 1,0 |
Cat. 5e Flexible U/UTP 4x2xAWG26/7