logo cavel

COAXIAL CABLES - antirodent - LSZH OUTER SHEATH DG80ZHROD

Legend
Legend
RG Ref. RG 59
Availability on demand
Application 4K-UHD
Indoor + Outdoor Installation
acc. to Standard EN50117-9-2
EN50117-10-2
CEI-UNEL 36762
Reaction to Fire EN50575
CONSTRUCTION DATA
Inner Conductor Ø mm 0,80
material Cu
Dielectric Ø mm 3,50
material PEG
Film Foil Laminate material APA
Braid material CuSn
Braid Optical Coverage % 65
Diameter over Braid Ø mm 4,00
Outer Sheath Ø mm 5
material LSZH
Sheatch armor Ø mm 7,8
material LSZH
PHYSICAL DATA
Copper Content kg/km 11,1
Cable Weight kg/km 90,0
Min bending radius x 1/n mm 40/80
Max.Tensile Strength N 90
ELECTRICAL DATA
Impedance Ohm 75±3@200 MHz
Capacitance (@1kHz) pF/m 52 ± 2
Velocity Ratio % 85
Attenuation (at 20°C )
at 5 MHz dB/100m 2,1
at 10 MHz dB/100m 3,0
at 30 MHz dB/100m 4,4
at 50 MHz dB/100m 5,7
at 200 MHz dB/100m 11,0
at 300 MHz dB/100m 13,5
at 470 MHz dB/100m 16,8
at 690 MHz dB/100m 20,4
at 1000 MHz dB/100m 24,9
at 1750 MHz dB/100m 33,5
at 2150 MHz dB/100m 37,4
at 2400 MHz dB/100m 39,6
at 3000 MHz dB/100m 44,8
Structural return loss (SRL)
at 5 - 470 MHz dB >30
at 470 - 1000 MHz dB >28
at 1000 - 2000 MHz dB >26
at 2000 - 3000 MHz dB >22
Transfer Impedance (Zt) Class B
5 - 30 MHz mOhm/m < 9
Screening Attenuation (SA) Class A
at 30 - 1000 MHz dB >90
at 1000 - 2000 MHz dB >75
at 2000 - 3000 MHz dB >65
DC Conductor Resistance inner/outer Ohm/km 35,0 / 18,6
Loop resistance Ohm/km 53,6
Sheat Insulation voltage (spark test) kV 2,5
Maximum current (Ieff) A 4
COAXIAL CABLES - antirodent - LSZH OUTER SHEATH
Standard Packing
  • 2 x 100m = 200m Plastic reel in Carton
    Single-unit Package Reel
    Item   DG80ZHRODMKP3519100
    Unith Length m 100 Unit Length Barcode EAN13 8000119440102
    Unit Packing Content m 2 x 100m = 200m Unit Packing Barcode EAN13 8000119430202