Class CPR acc. to UE 305/2011 (DoP) | Eca | |
Availability | in stock | |
Application | Primary (Campus), Secondary (Riser), Tertiary (Horizontal) | |
IPTV; HbbTV 2.0.n | ||
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T | ||
IEEE 802.5 16 MB: ISDN; TPDDI; ATM; PoE | ||
Indoor + Outdoor Installation | ||
acc. to Standard | ISO/IEC 11801 Class E | |
EN50288-5-1 | ||
EN50173 | ||
EIA-TIA 568 | ||
CEI-UNEL 36762 | ||
Reaction to Fire | EN50575 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 0,57 |
material | Cu | |
Insulation | Ø mm | 1,14 |
material | PE | |
Film Foil Laminate | material | Pet |
Film Foil | material | AP |
Outer Sheath | Ø mm | 7,8 |
material | LSZH | |
PHYSICAL DATA | ||
Copper Content | kg/km | 19,9 |
Cable Weight | kg/km | 59,1 |
Min bending radius x 1/n | mm | 35/70 |
Max.Tensile Strength | N | 100 |
ELECTRICAL DATA | ||
Impedance | Ohm | 100±5@100 MHz |
Capacitance of Twisted Pair (@800Hz) | pF/m | 48 |
Velocity Ratio | % | 67 |
Attenuation (at 20°C ) | ||
at 1 MHz | dB/100m | 1,8 |
at 10 MHz | dB/100m | 5,4 |
at 20 MHz | dB/100m | 7,7 |
at 31,2 MHz | dB/100m | 9,6 |
at 62,5 MHz | dB/100m | 13,7 |
at 100 MHz | dB/100m | 17,4 |
at 155,5 MHz | dB/100m | 21,9 |
at 250 MHz | dB/100m | 28,1 |
NEXT | ||
at 1 MHz | dB | 100,0 |
at 10 MHz | dB | 80,0 |
at 20 MHz | dB | 70,0 |
at 31,2 MHz | dB | 65,0 |
at 62,5 MHz | dB | 60,0 |
at 100 MHz | dB | 60,0 |
at 155,5 MHz | dB | 55,0 |
at 250 MHz | dB | 50,0 |
Coupling Attenuation | dB | > 45 |
Transfer Impedance (Zt) | ||
1 MHz | mOhm/m | < 35 |
10 MHz | mOhm/m | < 41 |
30 MHz | mOhm/m | < 110 |
100 MHz | mOhm/m | < 150 |
Screening Attenuation (SA) | ||
at 30 - 250 MHz | dB | > 50 |
DC Conductor Resistance | Ohm/km | 73,0 |
Loop resistance | Ohm/km | 146,0 |
Sheath Insulation Voltage (DC, 1 min) | kV | 1,0 |
Cat. 6 F/UTP 4x2xAWG23/1