| Availability | on demand | |
| Application | Work area, patch cord cable | |
| IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T | ||
| IEEE 802.5 16 MB: ISDN; TPDDI; ATM; PoE | ||
| acc. to Standard | EN50288-6-2 | |
| EN 50173 | ||
| CEI-UNEL 36762 | ||
| EN50575 | ||
| CONSTRUCTION DATA | ||
| Inner Conductor | Ø mm | 0,60 7x0,20 |
| material | CuSn | |
| Dielectric | Ø mm | 1,05 |
| material | PE | |
| Outer Sheath | Ø mm | 6,8 |
| material | PVC | |
| PHYSICAL DATA | ||
| Copper Content | kg/km | 17,3 |
| Cable Weight | kg/km | 45,4 |
| Min bending radius x 1/n | mm | 34/68 |
| Max.Tensile Strength | N | 100 |
| ELECTRICAL DATA | ||
| Impedance | Ohm | 100±5@100 MHz |
| Capacitance of Twisted Pair (@800Hz) | pF/m | 48 |
| Velocity Ratio | % | 67 |
| Attenuation (at 20°C ) | ||
| at 10 MHz | dB/10m | 0,9 |
| at 20 MHz | dB/10m | 1,28 |
| at 31,2 MHz | dB/10m | 1,61 |
| at 62,5 MHz | dB/10m | 2,32 |
| at 100 MHz | dB/10m | 2,99 |
| at 155,5 MHz | dB/10m | 3,79 |
| at 250 MHz | dB/10m | 4,95 |
| NEXT | ||
| at 10 MHz | dB | 60,3 |
| at 20 MHz | dB | 55,8 |
| at 31,2 MHz | dB | 52,9 |
| at 62,5 MHz | dB | 48,4 |
| at 100 MHz | dB | 45,3 |
| at 155,5 MHz | dB | 42,4 |
| at 250 MHz | dB | 39,3 |
| Coupling Attenuation | dB | > 45 |
| DC Conductor Resistance | Ohm/km | 85,0 |
| Loop resistance | Ohm/km | 170,0 |
| Sheath Insulation Voltage (DC, 1 min) | kV | 1,0 |
Cat. 6 Flexible U/UTP 4x2xAWG26/7