Availability | in stock | |
Application | Indoor Installation | |
acc. to Standard | MIL-C-17 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 2,25 7x0,75 |
material | Cu | |
Dielectric | Ø mm | 7,25 |
material | PE | |
Braid | material | Cu |
Braid Optical Coverage | % | 96 |
Diameter over Braid | Ø mm | 7,97 |
Outer Sheath | Ø mm | 10,3 |
material | PVC | |
PHYSICAL DATA | ||
Copper Content | kg/km | 75,26 |
Cable Weight | kg/km | 150,1 |
Min bending radius x 1/n | mm | 50/100 |
Max.Tensile Strength | N | 400 |
ELECTRICAL DATA | ||
Impedance | Ohm | 50±2 |
Capacitance (@1kHz) | pF/m | 101 ± 2 |
Velocity Ratio | % | 66 |
Attenuation (at 20°C ) | ||
at 50 MHz | dB/100m | 4,1 |
at 200 MHz | dB/100m | 9,0 |
at 300 MHz | dB/100m | 11,3 |
at 470 MHz | dB/100m | 14,8 |
at 800 MHz | dB/100m | 20,4 |
at 1000 MHz | dB/100m | 22,6 |
Structural return loss (SRL) | ||
at 30 - 300 MHz | dB | >25 |
at 300 - 600 MHz | dB | >24 |
at 600 - 1000 MHz | dB | >20 |
Screening Attenuation (SA) | Class | |
at 30 - 1000 MHz | dB | >55 |
DC Conductor Resistance inner/outer | Ohm/km | 5,5 / 4,5 |
Loop resistance | Ohm/km | 10,0 |
Sheat Insulation voltage (spark test) | kV | 5,0 |
RADIO FREQUENCY R COAXIAL CABLES