| Availability | in stock | |
| Application | Indoor Installation | |
| acc. to Standard | MIL-C-17 | |
| CONSTRUCTION DATA | ||
| Inner Conductor | Ø mm | 2,25 7x0,75 |
| material | Cu | |
| Dielectric | Ø mm | 7,25 |
| material | PE | |
| Braid | material | Cu |
| Braid Optical Coverage | % | 96 |
| Diameter over Braid | Ø mm | 7,97 |
| Outer Sheath | Ø mm | 10,3 |
| material | PVC | |
| PHYSICAL DATA | ||
| Copper Content | kg/km | 75,26 |
| Cable Weight | kg/km | 150,1 |
| Min bending radius x 1/n | mm | 50/100 |
| Max.Tensile Strength | N | 400 |
| ELECTRICAL DATA | ||
| Impedance | Ohm | 50±2 |
| Capacitance (@1kHz) | pF/m | 101 ± 2 |
| Velocity Ratio | % | 66 |
| Attenuation (at 20°C ) | ||
| at 50 MHz | dB/100m | 4,1 |
| at 200 MHz | dB/100m | 9,0 |
| at 300 MHz | dB/100m | 11,3 |
| at 470 MHz | dB/100m | 14,8 |
| at 800 MHz | dB/100m | 20,4 |
| at 1000 MHz | dB/100m | 22,6 |
| Structural return loss (SRL) | ||
| at 30 - 300 MHz | dB | >25 |
| at 300 - 600 MHz | dB | >24 |
| at 600 - 1000 MHz | dB | >20 |
| Screening Attenuation (SA) | Class | |
| at 30 - 1000 MHz | dB | >55 |
| DC Conductor Resistance inner/outer | Ohm/km | 5,5 / 4,5 |
| Loop resistance | Ohm/km | 10,0 |
| Sheat Insulation voltage (spark test) | kV | 5,0 |
RADIO FREQUENCY R COAXIAL CABLES