Availability | on demand | |
Application | Indoor Installation | |
acc. to Standard | MIL-C-17 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 0,90 |
material | CuAg | |
Dielectric | Ø mm | 2,95 |
material | PE | |
Braid | material | CuAg |
Braid Optical Coverage | % | 95 |
Diameter over Braid | Ø mm | 3,46 |
Outer Sheath | Ø mm | 5,4 |
material | PVC | |
PHYSICAL DATA | ||
Copper Content | kg/km | 35,6 |
Cable Weight | kg/km | 55,6 |
Min bending radius x 1/n | mm | 30/60 |
Max.Tensile Strength | N | 100 |
ELECTRICAL DATA | ||
Impedance | Ohm | 50±3 |
Capacitance (@1kHz) | pF/m | 104 ± 2 |
Velocity Ratio | % | 66 |
Attenuation (at 20°C ) | ||
at 50 MHz | dB/100m | 10,1 |
at 200 MHz | dB/100m | 19,5 |
at 300 MHz | dB/100m | 24,1 |
at 470 MHz | dB/100m | 31,0 |
at 800 MHz | dB/100m | 42,2 |
at 1000 MHz | dB/100m | 47,1 |
at 1500 MHz | dB/100m | 62,0 |
at 2000 MHz | dB/100m | 73,1 |
at 2500 MHz | dB/100m | 85,2 |
at 3000 MHz | dB/100m | 91,1 |
at 6000 MHz | dB/100m | 128,7 |
Structural return loss (SRL) | ||
at 30 - 300 MHz | dB | >27 |
at 300 - 600 MHz | dB | >25 |
at 600 - 1000 MHz | dB | >23 |
Transfer Impedance (Zt) | Class | A++ |
5 - 30 MHz | mOhm/m | < 0,9 |
Screening Attenuation (SA) | Class | A+ |
at 30 - 1000 MHz | dB | >90 |
at 1000 - 2000 MHz | dB | >90 |
at 2000 - 3000 MHz | dB | >80 |
DC Conductor Resistance inner/outer | Ohm/km | 28,0 / 6,5 |
Loop resistance | Ohm/km | 34,5 |
Sheath Insulation Voltage | kV | 5,0 |