Availability | on demand | |
Application | Indoor Installation | |
acc. to Standard | MIL-C-17 | |
CONSTRUCTION DATA | ||
Inner Conductor | Ø mm | 2,25 7x0,75 |
material | CuAg | |
Dielectric | Ø mm | 7,25 |
material | PE | |
Braid | material | CuAg |
Braid Optical Coverage | % | 95 |
Diameter over Braid | Ø mm | 7,89 |
Outer Sheath | Ø mm | 10,8 |
material | PVC | |
PHYSICAL DATA | ||
Copper Content | kg/km | 116,3 |
Cable Weight | kg/km | 196,4 |
Min bending radius x 1/n | mm | 50/100 |
Max.Tensile Strength | N | 500 |
ELECTRICAL DATA | ||
Impedance | Ohm | 50±2 |
Capacitance | pF/m | 100 ± 2 |
Velocity Ratio | % | 66 |
Attenuation (at 20°C ) | ||
at 50 MHz | dB/100m | 4,1 |
at 200 MHz | dB/100m | 9,0 |
at 300 MHz | dB/100m | 11,3 |
at 470 MHz | dB/100m | 14,8 |
at 800 MHz | dB/100m | 20,43 |
at 1000 MHz | dB/100m | 23,6 |
Structural return loss (SRL) | ||
at 30 - 300 MHz | dB | >23 |
at 300 - 600 MHz | dB | >22 |
at 600 - 1000 MHz | dB | >20 |
Transfer Impedance (Zt) | Class | A++ |
5 - 30 MHz | mOhm/m | < 0,9 |
Screening Attenuation (SA) | Class | A |
at 30 - 1000 MHz | dB | >85 |
at 1000 - 2000 MHz | dB | >75 |
at 2000 - 3000 MHz | dB | >75 |
DC Conductor Resistance inner/outer | Ohm/km | 5,5 / 4,0 |
Loop resistance | Ohm/km | 9,5 |
Sheath Insulation Voltage | kV | 5,0 |
RADIO FREQUENCY R COAXIAL CABLES